Search results for "Aortic repair"
showing 10 items of 14 documents
Assessment of EVAR Complications using CIRSE Complication Classification System in the UK Tertiary Referral Centre: A ∼6-Year Retrospective Analysis …
2021
Purpose: To retrospectively analyse complications in endovascular aortic repair (EVAR) interventions and evaluate if the CIRSE (Cardiovascular and Interventional Radiological Society of Europe) complication classification system is appropriate as a standardized classification tool for EVAR patients. Materials and Methods: Demographic, procedural and complication data in 719 consecutive patients undergoing EVAR at one institution from January 2014 to October 2019 were retrospectively reviewed. Data (imaging reports, procedural reports, nurse notes, discharge summary reports) were collected consulting the electronic patient record system (EPR) of the hospital and cleaned and stored in a Micro…
Biomechanical implications of excessive endograft protrusion into the aortic arch after thoracic endovascular repair
2015
Endografts placed in the aorta for thoracic endovascular aortic repair (TEVAR) may determine malappositioning to the lesser curvature of the aortic wall, thus resulting in a devastating complication known as endograft collapse. This premature device failure commonly occurs in young individuals after TEVAR for traumatic aortic injuries as a result of applications outside the physical conditions for which the endograft was designed. In this study, an experimentally-calibrated fluid-structure interaction (FSI) model was developed to assess the hemodynamic and stress/strain distributions acting on the excessive protrusion extension (PE) of endografts deployed in four young patients underwent TE…
Chimney and periscope grafts to facilitate endovascular treatment of aortic transection in a patient with aberrant right subclavian artery
2014
Purpose: To report the use of parallel grafts to extend the proximal landing zone for stentgraft repair of aortic transection involving an aberrant right subclavian artery (ARSA). Case Report: A 28-year-old patient was referred for treatment of traumatic aortic transection with contained rupture at the level of an ARSA. Immediate thoracic endovascular aortic repair (TEVAR) was planned because of hemodynamic instability. To achieve rapid sealing and maintain perfusion to both subclavian arteries, a chimney stent to the left subclavian artery (LSA) and a periscope stent-graft to the ARSA were deployed successfully. After surgical repair of all fractures, the patient was discharged 1 month aft…
Impact of Thoracic Endografting on the Hemodynamics of the Native Aorta: Pre- and Postoperative Assessments of Wall Shear Stress and Vorticity Using …
2021
Purpose To quantify the hemodynamic consequences of thoracic endovascular aortic repair (TEVAR) by comparing the preoperative and postoperative wall shear stress (WSS) and vorticity profiles on computational fluid dynamics (CFD) simulations. Materials and Methods The pre- and postoperative computed tomography (CT) scans from 20 consecutive patients (median age 69 years, range 20–87) treated for different thoracic aortic pathologies (11 aneurysms, 5 false aneurysms, 3 penetrating ulcers, and 1 traumatic aortic rupture) were segmented to construct patient-specific CFD models using a meshless code. The simulations were run over the cardiac cycle, and the WSS and vorticity values measured at th…
An In Vitro Phantom Study on the Role of the Bird-Beak Configuration in Endograft Infolding in the Aortic Arch.
2015
Purpose: To assess endograft infolding for excessive bird-beak configurations in the aortic arch in relation to hemodynamic variables by quantifying device displacement and rotation of oversized stent-grafts deployed in a phantom model. Methods: A patient-specific, compliant, phantom pulsatile flow model was reconstructed from a patient who presented with collapse of a Gore TAG thoracic endoprosthesis. Device infolding was measured under different flow and pressure conditions for 3 protrusion extensions (13, 19, and 24 mm) of the bird-beak configuration resulting from 2 TAG endografts with oversizing of 11% and 45%, respectively. Results: The bird-beak configuration with the greatest protr…
Risk of aortic dissection in patients with ascending aorta aneurysm: a new biological, morphological, and biomechanical network behind the aortic dia…
2020
Thoracic aortic aneurysm represents a deadly condition, particularly when it evolves into rupture and dissection. Proper surgical timing is the key to positively influencing the survival of patients with this pathology. According to the most recent guidelines, ascending aorta size ≥ 55 mm and a rate of growth ≥ 0.5 cm per year are the most important factors for surgical indication. Nevertheless, a lot of evidence show that aortic ruptures and dissections might occur also in small size ascending aorta. In this review, we sought to analyze a new biological and morphological network behind the aortic diameter that need to be considered in order to identify the portion of patients with thoracic…
Peroperative Intravascular Ultrasound for Endovascular Aneurysm Repair versus Peroperative Angiography: A Pilot Study in Fit Patients with Favorable …
2020
The aim of this study was to compare intravascular ultrasound (IVUS) assistance for endovascular aortic aneurysm repair (EVAR) to standard assistance by angiography.From June 2015 to June 2017, 173 consecutive patients underwent EVAR. In this group, 69 procedures were IVUS-assisted with X-ray exposure limited to completion angiography for safety purposes because an IVUS probe does not yet incorporate a duplex probe (group A), and 104 were angiography-assisted procedures (group B). All IVUS-assisted procedures were performed by vascular surgeons with basic duplex ultrasound (DUS) training. The primary study endpoints were mean radiation dose, duration of fluoroscopy, amount of contrast media…
Aortic remodelling after thoracic endovascular aortic repair in acute and chronic type B aortic dissections
2019
AbstractOBJECTIVESType B aortic dissections are routinely treated with thoracic endovascular aortic repair (TEVAR). The timing for TEVAR remains controversial and might have an impact on the remodelling capacity of the aorta. This study analyses and compares aortic remodelling in acute (ABD) and chronic (CBD) type B aortic dissections after TEVAR.METHODSThis retrospective study analysed the preoperative, postoperative and at least 1-year follow-up computed tomography of 53 TEVAR patients (36 ABD, 17 CBD) at a single institution between May 2005 and May 2016. The volumes of aortic lumen (AL), true lumen, false lumen (FL) and perfused FL were measured at the stent graft level (A), from the st…
Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?
2011
Thoracic endovascular aortic repair (TEVAR) has emerged as a promising therapeutic alternative to conventional open aortic replacement but it requires suitable proximal and distal landing zones for stent-graft anchoring. Many aortic pathologies affect in the immediate proximity of the left subclavian artery (LSA) limiting the proximal landing zone site without proximal vessel coverage. In patients in whom the distance between the LSA and aortic lesion is too short, extension of the landing zone can be obtained by covering the LSA's origin with the endovascular stent graft (ESG). This manoeuvre has the potential for immediate and delayed neurological and vascular symptoms. Some authors, ther…
Current role of the chimney technique in the treatment of complex abdominal aortic pathologies: A position paper from the PERICLES Registry investiga…
2020
Historically, chimney/snorkel endovascular aortic repair (Ch-EVAR) emerged as a rescue technique to revascularize and/or preserve inadvertently covered critical branch vessels during infrarenal aortic endografting. Next, in its evolutionary path, Ch-EVAR offered a viable treatment option for complex aortic repair, and particularly in situations where fenestrated/ branched EVAR was not a therapeutic option due to the lack of availability and/or anatomical constraints. In this context, this technique offered distinct advantages such as off-the-shelf availability, straightforward implantation techniques, and lower resource use-intensity enabling performance by a large number of operators manag…